TrisoWIKA1

Trisonischer Windkanal
















Compressor System:   Operating pressure: 20 bar, delivery volume: 1600 qm/h
                                     Suction pressure: ambient pressure

Pressure Vessel:          Volume: 2 x 190 m³, operating pressure: max. 20 bar
                                     Operating temperature: -40°C to +40°C

Pressure Regulation:   Operating pressure: 1.2 - 5 bar, time for opening/closing: < 1 sec
                                     Pressure tolerance: < 5 mbar, max. flow rate: 250 kg/s

Settling Chamber:        Volume: 8.5 m², Operating pressure: 20 bar

Laval Nozzle:               Mach number: 0.3 - 3.0, tolerance: < 0.005
                                     Adjustment time: < 30 sec

Test Section:               Height: 675 mm, width: 300 mm 
                                    Cross sectional area: 0.2025 m²
                                    Horizontal walls: slotted / plain
                                    Vertical walls: perforated/ plain

Diffuser:                      Operating pressure: 0.05 - 5 bar
                                    Time for opening/closing: < 10 sec
                                    Time for emergency opening: < 1 sec

Hydraulic System:       Delivery pressure: max. 210 bar, air escape: 130 - 140 bar
                                    Flow rate: 75 ltr/min
 

 

TWM Data Sheet

Mass Flow and Blow-Out Time as a Function of the Mach Number

Download > TWM Data Sheet